REI|TALAN™ |3.0 Telephone & Line Analyzer REI TSCM REI|TALAN™ |3.0 Telephone & Line Analyzer HD International.
REI|TALAN™ |3.0 Telephone & Line Analyzer REI TSCM REI|TALAN™ |3.0 Telephone & Line Analyzer HD International.
REI|TALAN™ 3.0 Telephone & Line Analyzer
REI|TALAN™ 3.0 Telephone & Line Analyzer
REI|TALAN™ 3.0 Telephone & Line Analyzer

REI|TALAN™ 3.0 Telephone & Line Analyzer

Telephone and Line Analyzer for Wire Tap Detection and Line Security Testing

TALAN® 3.0 is designed to detect and locate illicit tampering and security vulnerabilities on digital, analog, and VoIP telephone systems.

Combining multimeter testing, RF broadband detection, spectrum analysis, FDR, NLJD, digital demodulation, and VoIP analysis tools, TALAN® 3.0 supports professional telephone line inspection and TSCM operations.

Digital / Analog / VoIP Telephone system inspection
Up to 8 GHz RF broadband detector input
30 kHz–85 MHz Spectrum analyzer range
4 hours Typical battery runtime
Product Overview

Telephone and Line Analyzer for Detecting Wire Taps and Eavesdropping

TALAN® 3.0 is designed to detect and locate illicit tampering and security vulnerabilities on digital, analog, and VoIP telephone systems. It can test twisted pairs against modern telecommunication threats, including shield and ground.

01

Multi-Test Platform

Combines voltage, current, resistance, capacitance, non-linear junction detection, frequency domain reflectometry, and digital demodulation in one analyzer.

02

Automatic Pair Switching

Internal pair switching matrix performs tests on all pair combinations, helping compare results across multiple phone lines and identify anomalies.

03

VoIP Traffic Analysis

Advanced VoIP traffic filtering and FFT-based spectrum view help identify suspicious packet information and visual traffic patterns.

04

RF Broadband Detection

RF broadband detector supports testing for RF energy, with RF SMB input up to 8 GHz and line level testing from 100 kHz to 600 MHz.

05

FDR & NLJD Functions

Frequency Domain Reflectometer checks for taps on a line, while NLJD functionality helps detect electronics connected to the line.

06

Data Viewer Software

TALAN Data Viewer Software helps organize, analyze, compare, and export saved test sequence data and charts for report writing.

TALAN 3.0 Telephone and Line Analyzer
TALAN® 3.0 Telephone and Line Analyzer
Line Testing

Integrated Countermeasure Testing Capabilities

TALAN® 3.0 integrates multiple telephone and line inspection functions into one portable system for professional TSCM and telephone line analysis work.

  • Multimeter tests: voltage, current, resistance, capacitance
  • RF Broadband Detector up to 8 GHz
  • Spectrum Analyzer up to 85 MHz
  • High Gain Audio Amplifier
  • Bias Generator ±80 VDC
  • Audio Oscilloscope with active input, 20 Hz to 20 kHz
Interface & Analysis

Analysis Tools for RF, VoIP, Resistance, and NLJD Testing

TALAN® 3.0 provides multiple inspection and analysis modes to support telephone line testing, VoIP analysis, RF spectrum review, and connected electronics detection.

TALAN 3.0 RF Spectrum

RF Spectrum

Spectrum analyzer mode supports RF spectrum review from 30 kHz to 85 MHz.

TALAN 3.0 VoIP Plus Analysis

VoIP Plus Analysis

VoIP traffic filtering helps locate and identify suspicious packet information.

TALAN 3.0 NLJD

NLJD Functionality

Non-Linear Junction Detector functionality supports detection of electronics connected to a line.

TALAN 3.0 Resistance Testing
Resistance testing for telephone line inspection
Testing Workflow

Compare Results Across Multiple Lines

The multi-test database system stores test data for historical comparison and comparison against other lines, helping operators identify threatening anomalies more efficiently.

  • Test all pair combinations
  • Compare multiple phone lines
  • Store data for historical review
  • Export results for further analysis and reporting
  • Use TALAN Data Viewer Software for chart review and report writing
Applications

Typical Application Areas

Application areas below are based on published TALAN® 3.0 product information.

  • Technical Surveillance Countermeasures (TSCM)
  • Counter Surveillance
  • Wire Tap Detection
  • Telephone Line Testing
  • Phone Line Analysis
  • Eavesdropping Detection
  • Intelligence Protection
  • Executive Protection
  • Surveillance Equipment Detection
  • Electronic Surveillance Detection
Technical Specifications

TALAN® 3.0 Specifications

Specifications below are based on published TALAN® 3.0 product information.

Category Specification
Product Type Telephone and Line Analyzer
Telephone Systems Digital, analog, and VoIP telephone systems
Primary Computer 32 bit RISC processor, 520 MHz
Internal Memory 64 MB SDRAM (OS), 64 MB Flash
External Memory Compact Flash Type III, USB mass storage
Network 10/100 Ethernet Controller for IP Packet Detection
USB USB Device (A Type) supports external keyboard, mouse, and USB mass storage device; USB Host (B type) for future use
Analog I/O 3.5 mm mono headphone output; 3.5 mm mono microphone input
User Interface 6 soft menu keys, 5 button quadrant navigation, dedicated keys, high-resolution optical encoder, integrated touch screen with stylus
Test Inputs Dual MOD8; banana type sockets for ring, tip, and earth; SMB RF input; expansion port; all inputs electrically isolated
Spectrum Analyzer Dual conversion, super-heterodyne receiver; 30 kHz to 85 MHz; 2 second sweep time; 1 kHz step size; 18 kHz bandwidth; -100 dBm sensitivity
Broadband Detector RF SMB input to 8 GHz; line level test 100 kHz to 600 MHz; -65 dBm sensitivity
Digital Multimeter Quick response auto-ranging; 500 msec sample rate
AC / DC Volts 0 to 250 V maximum
AC / DC Current 0 to 300 mA maximum
Resistance 0 to 42 MΩ
Capacitance 50 pF to 40 µF
Bias Generator Optically isolated, direct digital control; output ceiling ±80 V; shield output ceiling ±65 VDC, ±33 VAC
Bias Modulation Fixed voltage or variable rate sine wave, 10 Hz to 300 Hz
Audio Bandwidth 20 Hz to 20 kHz
Audio Gain Up to 80 dB total system gain (voice band)
Audio AGC Digitally controlled automatic gain
Audio Filter Analog voice band filter, 300 Hz to 3 kHz
Power Input 15 VDC @ 3A external input; universal power supply 100–240 VAC, 50–60 Hz
Battery Removable rechargeable lithium-ion battery
Run Time 4-hour runtime, typical
Unit Dimensions 10 × 12.9 × 2.7 in / 25.4 × 32.8 × 6.9 cm
Unit Weight 6 lbs / 2.7 kg with battery
Case Dimensions 19.5 × 14.9 × 5.4 in / 49.5 × 37.8 × 13.7 cm
Case Weight 19 lbs / 7.1 kg including unit and accessories
Operating Temperature 0°C to +50°C

Note: Specifications and included accessories may vary by product updates or final configuration. Please confirm final package details before publication.

Request TALAN® 3.0 Information

Contact HDX International for quotation, availability, configuration details, and product information.